Acquiring multi-echo data

Available multi-echo fMRI sequences

We have attempted to compile some basic multi-echo fMRI protocols in an OSF project. The parameter choices in these protocols run and seem reasonable, but they have not been optimized for a specific situation. They are a good starting point for someone designing a study, but should not be considered canonical. If you would like to use one of them, please customize it for your own purposes and make sure to run pilot scans to test your choices.

Siemens

For Siemens users, there are two options for Works In Progress (WIPs) Sequences.

  • The Center for Magnetic Resonance Research at the University of Minnesota
    provides a custom MR sequence that allows users to collect multiple echoes
    (termed Contrasts). The sequence and documentation can be found here.
    For details on obtaining a license follow this link.
    By default the number of contrasts is 1, yielding a single-echo sequence.
    In order to collect multiple echoes, increase number of Contrasts on the
    Sequence Tab, Part 1 on the MR console.
  • The Martinos Center at Harvard also has a MR sequence available, with the
    details available here. The number of echoes can be specified on the
    Sequence, Special tab in this sequence.

GE

For GE users, there are currently two sharable pulse sequences:

  • Multi-echo EPI (MEPI) – Software releases: DV24, MP24 and DV25 (with offline recon)

  • Hyperband Multi-echo EPI (HyperMEPI) - Software releases: DV26, MP26, DV27, RX27
    (here hyperband can be deactivated to do simple Multi-echo EPI – online recon)

Please reach out to the GE Research Operation team or each pulse sequence’s author to begin the process of obtaining this software. More information can be found on the GE Collaboration Portal

Once logged in, go to Groups > GE Works-in-Progress you can find the description of the current ATSM (i.e. prototypes).

Philips

For Philips users, sequences can be defined using product software.

Multi-echo EPI (ME-EPI) can be acquired using the product software and can be combined with SENSE parallel imaging and MultiBand. The combination with MultiBand requires a SW release >R5.1 and MultiBand functionality to be present. No default ME-EPI are provided, but existing single-echo EPI sequences from the BOLD fMRI folder can be modified into multi-echo sequences by increasing the number of echoes. As a starting point to develop a 3 echo EPI protocol start by opening the default fMRI protocol and modify the following: increase number of echoes to 3 on the Contrast tab, set SENSE = 3, MB-SENSE = 3, set to 3mm isotropic voxels and adjust TEs to your preference.

Other available multi-echo MRI sequences

In addition to ME-fMRI, other MR sequences benefit from acquiring multiple echoes, including T1-weighted imaging (MEMPRAGE) and susceptibility weighted imaging. While most of these kinds of sequences fall outside the purview of this documentation, quantitative T2* mapping is relevant since a baseline T2* map is used in several processing steps including Optimal combination. While the T2* map estimated directly from fMRI time series is noisy, no current study quantifies the benefit to optimal combination or tedana denoising if a higher quality T2* map is used. Some benefit is likely, so, if a T2* map is independently calculated, it can be used as an input to many functions in the tedana workflow.

Warning

While tedana allows the input of a T2* map from any source, and a more accurate T2* map should lead to better results, this hasn’t been systematically evaluated yet.

There are many ways to calculate T2* maps, with some using multi-echo acquisitions. We are not presenting an expansive review of this literature here, but Cohen-Adad et al. (2012) and Ruuth et al. (2019) are good places to start learning more about this topic.

Acquisition parameter recommendations

There is no empirically tested best parameter set for multi-echo fMRI acquisition. The guidelines for optimizing parameters are similar to single-echo fMRI. For multi-echo fMRI, the same factors that may guide priorities for single echo fMRI sequences are also relevant. Choose sequence parameters that meet the priorities of a study with regards to spatial resolution, spatial coverage, sample rate, signal-to-noise ratio, signal drop-out, distortion, and artifacts.

A minimum of 3 echoes is required for running the current implementation fo TE-dependent denoising in tedana. It may be useful to have at least one echo that is earlier and one echo that is later than the TE one would use for single-echo T2* weighted fMRI.

Note

This is in contrast to the dual echo denoising method which uses a very early (~5ms) first echo in order to clean data. For more information on this method, see Bright and Murphy (2013).

More than 3 echoes may be useful, because that would allow for more accurate estimates of BOLD and non-BOLD weighted fluctuations, but more echoes have an additional time cost, which would result in either less spatiotemporal coverage or more acceleration. Where the benefits of more echoes balance out the additional costs is an open research question.

We are not recommending specific parameter options at this time. There are multiple ways to balance the slight time cost from the added echoes that have resulted in research publications. We suggest new multi-echo fMRI users examine the Publications using multi-echo fMRI that use multi-echo fMRI to identify studies with similar acquisition priorities, and use the parameters from those studies as a starting point. More complete recommendations and guidelines are discussed in the appendix of Dipasquale et al. (2017).

Note

In order to increase the number of contrasts (“echoes”) you may need to first increase the TR, shorten the first TE and/or enable in-plane acceleration. For typically used parameters see the ME-fMRI parameters section below.

ME-fMRI parameters

The following section highlights a selection of parameters collected from published papers that have used multi-echo fMRI. You can see the spreadsheet of publications at Publications using multi-echo fMRI.

The following plots reflect the average values for studies conducted at 3 Tesla.

(Source code, png, hires.png, pdf)

_images/acquisition-1_00_00.png

(png, hires.png, pdf)

_images/acquisition-1_01_00.png

(png, hires.png, pdf)

_images/acquisition-1_02_00.png